QT048
GENERAC 4.2L ENGINE
• Allinputconnectionsinonesinglearea
• Highcoolanttemperatureshutdown
• Lowoilpressureshutdown
• Lowcoolantlevelautomaticshutdown
• Overspeedautomaticshutdown
• Cranktimer
• Exercisetimer
• Oildrainextension
• Coolflowradiator
• Closedcoolantrecoverysystem
• UV/Ozoneresistanthoses
• Watertightstateoftheartelectricalconnectors
• Mainlinecircuitbreaker
• Radiatordrainextension
• Batterychargealternator
• 2Ampstaticbatterycharger
• Batterycables
• Batteryrack
• Fanandbeltguards
• Isochronousgovernor
• Flexfuelline
• Hourmeter
STANDARD EQUIPMENT
Liquid Cooled Gas Engine Generator Sets
Standby Power Rating
48 kW 60 Hz
Naturally Aspirated
Gaseous Fueled
• Innovativedesignandfullyprototypetested
• UL2200Listed
• Solidstatefrequencycompensated
voltageregulator
• Dynamicandstaticbatterycharger
• Soundattenuatedacousticallydesignedenclosure
• Quiettestforlownoiselevelexercise
• Acousticallydesignedenginecoolingsystem
• Highflowlownoisefactoryengineeredexhaustsystem
• State of the art digital control system with R100 digital
controlpanel
• Watertightelectricalconnectors
• Rodentproofconstruction
• High efficiency, low distortion Generac designed
alternator
• Vibrationisolatedfrommountingbase
• Matching Generac transfer switches engineered and
testedtoworkasasystem
• Allcomponentseasilyaccessibleformaintenance
• Electrostaticallyappliedpowderpaint
FEATURES
Vedere la pagina 0
1 2 3 4

Sommario

Pagina 1 - FEATURES

QT048 GENERAC 4.2L ENGINE• Allinputconnectionsinonesinglearea• Highcoolanttemperatureshutdown• Lowoilpressureshutdown• Lowcoolantlev

Pagina 2 - C to 70 °C

APPLICATION& ENGINEERING DATARating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage.

Pagina 3 - OPERATING DATA

OPERATING DATAQT048RATING: Allthreephaseunitsareratedat0.8powerfactor.Allsinglephaseunitsareratedat1.0powerfactor.STANDBYRATING:

Pagina 4 - INSTALLATION LAYOUT

QT048INTERCONNECTIONS48/46 240 1Ø 200 #6 to 300 mcm48/46 208 3Ø 175 #6 to 300 mcm48/46 240 3Ø 150 #6 to 300 mcm48/46 480 3Ø 80 #6 to 300 m